00:00:00.080 --> 00:00:06.056
When you live in a cold place like I do, these&nbsp;
whole home humidifiers are great.

00:00:06.056 --> 00:00:11.080
Which is why it's such a shame that they're also so terrible.

00:00:11.080 --> 00:00:12.874
What do I mean by that?

00:00:12.874 --> 00:00:17.006
Well, if you've got one of these or you are looking into getting one,

00:00:17.006 --> 00:00:22.052
you&nbsp;should be aware that they need much more attention from you than you might expect.

00:00:22.052 --> 00:00:29.385
Not only can these&nbsp;rather easily fail in such a way that can cause catastrophic damage to your home's heating system,

00:00:29.385 --> 00:00:36.159
but they can also cause significant damage to your home itself if you simply let them run unattended.

00:00:36.159 --> 00:00:38.376
See, the thing that makes them great -

00:00:38.376 --> 00:00:43.994
the ability to add lots of moisture to the air 
very quickly&nbsp;without you having to do anything

00:00:43.994 --> 00:00:49.199
- also makes them a problem 
when the temperature outside gets very&nbsp;cold.

00:00:49.199 --> 00:00:56.264
But today, I am going to fix that problem 
by giving it just a little more smarts than it had&nbsp;before.

00:00:56.264 --> 00:00:58.487
First though, a little backstory.

00:00:58.487 --> 00:01:02.805
In 2021, I made a video on freestanding humidifiers,

00:01:02.805 --> 00:01:08.754
and&nbsp;the comments were filled with folks wondering why I didn't talk about centrally ducted humidifiers&nbsp;like this one

00:01:08.754 --> 00:01:11.119
beyond a basic mention.

00:01:11.119 --> 00:01:16.604
Well, partly that's because back then I was living in&nbsp;a different home and I didn't have one of these.

00:01:16.604 --> 00:01:21.061
But the bigger reason was that if you want to add&nbsp;a humidifier,

00:01:21.061 --> 00:01:27.992
it's a lot easier and cheaper to buy one that you 
just plop somewhere and fill with&nbsp;water.

00:01:27.992 --> 00:01:32.744
Many of them are large enough 
to work just fine as a whole-home humidifier.

00:01:32.744 --> 00:01:37.004
Plus, freestanding&nbsp;units don't care 
what kind of heating system you have.

00:01:37.004 --> 00:01:41.884
So, if your home is heated with radiators&nbsp;
or some other kind of ductless heating system,

00:01:41.884 --> 00:01:43.574
like certain kinds of heat pump,

00:01:43.574 --> 00:01:45.530
those will work&nbsp;fine.

00:01:45.530 --> 00:01:51.092
The humidifier I'm talking about today 
requires both a centrally ducted heating system

00:01:51.092 --> 00:01:54.125
and a plumbed connection to a water line.

00:01:54.125 --> 00:01:57.850
So, it's not universal and it's much more involved.

00:01:57.850 --> 00:02:04.800
And as&nbsp;I already said, these things come with significant risks that you really need to be aware of and&nbsp;monitoring.

00:02:04.800 --> 00:02:10.055
I'll explain those shortly, but let's start 
with a quick overview of what this thing&nbsp;is.

00:02:10.055 --> 00:02:14.729
There are several types of these things on the market, 
but most of them are similar to this one.

00:02:14.729 --> 00:02:21.230
Inside is simply a fan which blows air 
through this wet pad made of absorbent material.

00:02:21.230 --> 00:02:26.670
The whole&nbsp;thing is mounted to a giant hole 
cut into my HVAC system's duct work.

00:02:26.670 --> 00:02:32.225
And when it's running, the&nbsp;fan draws in some of the air coming up from the furnace through the sides here

00:02:32.225 --> 00:02:37.883
and then forces&nbsp;it through that wet pad where it will absorb moisture before rejoining the airstream

00:02:37.883 --> 00:02:40.150
and getting&nbsp;distributed throughout my home.

00:02:40.150 --> 00:02:42.249
It's quite a simple device.

00:02:42.249 --> 00:02:44.365
Where's the water coming from?

00:02:44.365 --> 00:02:46.272
It's&nbsp;coming from right here.

00:02:46.272 --> 00:02:53.052
When the humidifier is running, this solenoid valve opens 
and a small but&nbsp;steady stream of water is fed through this line

00:02:53.052 --> 00:02:58.171
and up to this nozzle where it's then distributed&nbsp;
through these drip holes and onto the pad.

00:02:58.171 --> 00:03:00.443
That makes the pad soaking wet.

00:03:00.443 --> 00:03:05.197
And in fact, once it's&nbsp;saturated, 
you'll see a trickle of water coming out the bottom.

00:03:05.197 --> 00:03:10.520
The valve is deliberately letting&nbsp;more water through 
than the air going through the pad can absorb.

00:03:10.520 --> 00:03:14.322
So, you invariably end up with&nbsp;some wasted water.

00:03:14.322 --> 00:03:17.331
I couldn't tell you exactly how much water is being lost here,

00:03:17.331 --> 00:03:23.215
but I can tell&nbsp;you I have never noticed an increase 
in my water bill between heating and cooling seasons.

00:03:23.215 --> 00:03:25.048
So, it's&nbsp;not that much.

00:03:25.048 --> 00:03:30.514
But if you're concerned about that, there are water-saving models available which&nbsp;don't work like this one does.

00:03:30.514 --> 00:03:34.119
But, they have other considerations 
which I'm not going to be&nbsp;getting into today.

00:03:34.119 --> 00:03:41.261
Since the pad is essentially always soaking wet, 
it gets pretty gross and needs&nbsp;regular replacement.

00:03:41.261 --> 00:03:47.430
How often you'll need to do that depends largely on 
your water hardness and&nbsp;how large your home is.

00:03:47.430 --> 00:03:50.843
I have a fairly small home, so this thing doesn't run that much

00:03:50.843 --> 00:03:55.094
and&nbsp;I can usually get away with changing 
it at the start of each heating season.

00:03:55.094 --> 00:04:00.548
But even still, this&nbsp;is what last year's pad looks like.

00:04:00.548 --> 00:04:06.583
It used to be white and now it's pink and crunchy because of all&nbsp;the calcium it's filled with.

00:04:06.583 --> 00:04:08.691
Delicious!

00:04:08.691 --> 00:04:12.414
But it can be much worse than simply getting a little&nbsp;gross.

00:04:12.414 --> 00:04:16.459
Remember that thing I said about these needing much more attention than you might expect?

00:04:16.459 --> 00:04:21.241
Well, one day I heard the water valve open, but I didn't hear the fan start up.

00:04:21.241 --> 00:04:30.068
And that was because&nbsp;the pad had started to deteriorate and part of it fell forward and into the fan blades, holding&nbsp;them stationary.

00:04:30.068 --> 00:04:36.874
I'm honestly quite lucky that it didn't cause any damage to my furnace because the&nbsp;water valve was still open and getting it wet.

00:04:36.874 --> 00:04:43.544
So, the pad's detached section leaning at a wonky&nbsp;angle could easily have started dripping water down into the furnace.

00:04:43.544 --> 00:04:50.789
And when I was a little&nbsp;kid, my mom and dad had that exact thing happen which fried the furnace's control board.

00:04:50.789 --> 00:04:53.460
So,&nbsp;yeah, these are not set and forget -

00:04:53.460 --> 00:04:58.804
you really need to be cognizant of their operation and&nbsp;
needs and should be checking on it regularly.

00:04:59.520 --> 00:05:04.221
But anyway, you'll notice that the water line&nbsp;
is being fed by my water heater.

00:05:04.221 --> 00:05:09.972
This style of humidifier generally works better when the water&nbsp;
which is saturating the pad is hot.

00:05:09.972 --> 00:05:16.329
In fact, the manufacturer claims it needs hot water&nbsp;
if you're going to use this humidifier...

00:05:16.329 --> 00:05:19.007
Well, hold on. That part comes later.

00:05:19.007 --> 00:05:26.168
Now, since this&nbsp;is just a fan that grabs some air from the duct, gets it moist, and then puts it back into&nbsp;the duct,

00:05:26.168 --> 00:05:31.389
it relies on the furnace pushing air through the duct work in order to distribute&nbsp;its work

00:05:31.389 --> 00:05:34.769
and actually increase the humidity in my home.

00:05:34.769 --> 00:05:41.196
And that means if it were for some reason&nbsp;
running when the furnace's blower wasn't,

00:05:41.196 --> 00:05:44.238
well, it would pretty quickly cause a problem.

00:05:44.238 --> 00:05:52.012
The&nbsp;air in that duct work would get extremely humid and water would start condensing onto things&nbsp;which ought not get wet.

00:05:52.012 --> 00:05:54.430
Luckily, there's an easy solution to that:

00:05:54.430 --> 00:06:00.277
only power this thing up if&nbsp;the furnace is running 
and blowing air through the ducts.

00:06:00.277 --> 00:06:03.535
That water valve is powered by 24 volts AC,

00:06:03.535 --> 00:06:10.602
the same power that your furnace or air handler produces to send through your thermostat wiring&nbsp;for control signaling.

00:06:10.602 --> 00:06:15.528
The humidifier is also plugged into 
120 volt line voltage for its fan&nbsp;motor,

00:06:15.528 --> 00:06:21.988
but the fan is controlled via a current sensing relay which detects that the water valve&nbsp;is open.

00:06:21.988 --> 00:06:25.911
So if the water valve is open, the fan will run.

00:06:25.911 --> 00:06:34.294
This ultimately means if you wire that&nbsp;water valve across the common wire and the heat signal wire coming from the thermostat,

00:06:34.294 --> 00:06:40.499
then the&nbsp;humidifier will only be able to operate 
when your thermostat is calling for heat.

00:06:40.499 --> 00:06:45.123
This setup not&nbsp;only ensures the blower 
will be running when the humidifier is on,

00:06:45.123 --> 00:06:49.254
but it also means the humidifier&nbsp;
won't run during a cooling call.

00:06:49.254 --> 00:06:53.721
So, if you forget to switch it off at the end 
of the heating season,&nbsp;it's no big deal.

00:06:53.721 --> 00:06:57.687
But the humidifier can't simply run whenever the heat's on.

00:06:57.687 --> 00:07:04.607
That would likely&nbsp;result in over-humidification, which could be uncomfortable or even cause mold issues.

00:07:04.607 --> 00:07:11.738
So rather&nbsp;than hook the water valve to the furnace directly, 
its power wire goes through this humidistat.

00:07:11.738 --> 00:07:13.505
This&nbsp;is a fully analog doodad

00:07:13.505 --> 00:07:20.547
which sits in the return air stream and closes a switch when the humidity&nbsp;is lower than your desired set point.

00:07:20.547 --> 00:07:27.167
So long as that switch is closed and the thermostat 
is&nbsp;calling for heat, then the humidifier will run.

00:07:27.167 --> 00:07:32.273
But once the humidifier has elevated humidity&nbsp;
to your set point, that switch will open

00:07:32.273 --> 00:07:36.672
and the humidifier will shut off 
even if the heat is still&nbsp;running.

00:07:36.672 --> 00:07:39.872
It's a very simple control setup, but it works great!

00:07:39.872 --> 00:07:42.188
Except for when it doesn't.

00:07:42.188 --> 00:07:50.110
First&nbsp;of all, you may remember from a previous video of mine that my home's furnace is oversized by nearly&nbsp;a factor of four.

00:07:50.110 --> 00:07:54.888
This means on most days, 
it only runs for two, maybe 3 hours.

00:07:54.888 --> 00:07:59.729
And that's not enough&nbsp;time 
for the humidifier to actually be effective.

00:07:59.729 --> 00:08:04.580
That's a problem specific to my home, but it was&nbsp;very annoying.

00:08:04.580 --> 00:08:12.344
I couldn't get the indoor humidity to even touch 40% 
when I wanted it closer to 45 or&nbsp;even 50.

00:08:12.344 --> 00:08:15.359
However, there was a fix for this issue.

00:08:15.359 --> 00:08:22.704
Instead of hooking the humidifier's water valve&nbsp;
to the heat signal wire, I changed it to the fan signal wire.

00:08:22.704 --> 00:08:27.976
This meant the humidifier was able&nbsp;
to run so long as my thermostat was calling for the blower fan.

00:08:27.976 --> 00:08:34.560
And by setting a fan schedule on&nbsp;my thermostat, 
which ensured the fan ran for 15 minutes every hour,

00:08:34.560 --> 00:08:37.937
my humidifier was actually&nbsp;able to do its job.

00:08:37.937 --> 00:08:43.184
And for the last couple of years, 
I've been enjoying delightfully moist air&nbsp;in the winter,

00:08:43.184 --> 00:08:46.453
nice and comfy and free of static shocks.

00:08:46.453 --> 00:08:51.974
This scenario is why the manufacturer&nbsp;
wants this thing hooked to hot water.

00:08:51.974 --> 00:08:59.581
If it's running during a heating call, the air the&nbsp;humidifier is taking from the furnace and blowing past the pad will be hot,

00:08:59.581 --> 00:09:02.081
which will help water to&nbsp;evaporate.

00:09:02.081 --> 00:09:09.141
But if it's running during a fan call, that air is only at room temperature and the&nbsp;water won't evaporate as quickly.

00:09:10.390 --> 00:09:15.201
Honestly though, I have a hunch it would actually work fine if it&nbsp;
were hooked up to cold water,

00:09:15.201 --> 00:09:22.864
and the real reason they want it hooked to hot water is to minimize&nbsp;the cooling which would occur as water evaporates.

00:09:22.864 --> 00:09:28.981
This thing is basically a swamp cooler and it will&nbsp;
drop the temperature of the air leaving the vents if it's running.

00:09:28.981 --> 00:09:35.782
But if the pad is soaked in hot&nbsp;water, that cooling effect is diminished somewhat and possibly even eliminated.

00:09:35.782 --> 00:09:37.584
But anyway, that's&nbsp;not important.

00:09:37.584 --> 00:09:42.001
What is important is this little 
note you may have spotted on the humidistat.

00:09:42.001 --> 00:09:47.873
This&nbsp;thing wants you to turn the humidity 
set point down as the outdoor temperature falls.

00:09:47.873 --> 00:09:54.722
This is&nbsp;because the colder it is outside, the colder the inside surface of your walls and windows becomes

00:09:54.722 --> 00:09:57.731
and that will encourage condensation.

00:09:57.731 --> 00:10:02.433
This could simply be an inconvenience - maybe you'll have some&nbsp;water puddling on window sills.

00:10:02.433 --> 00:10:07.042
But it could also lead to mold growth 
inside your exterior walls.

00:10:07.327 --> 00:10:11.091
And you don't want that, 
which is why it has this helpful little note.

00:10:11.091 --> 00:10:14.676
There's just one small&nbsp;problem with notes like this, though.

00:10:14.676 --> 00:10:20.146
You're lucky if people read them, and you're even luckier&nbsp;if people remember about them.

00:10:20.146 --> 00:10:23.819
I'm a people and I have forgotten about this several times.

00:10:23.819 --> 00:10:29.900
Usually&nbsp;what happens is the temperature plummets overnight and when I get up, the windows are soaking wet.

00:10:29.900 --> 00:10:32.806
So&nbsp;then I go downstairs to the furnace closet -

00:10:32.806 --> 00:10:35.000
quick reminder for you homebuilders out there,

00:10:35.000 --> 00:10:36.946
this can&nbsp;all just go in a closet!

00:10:36.946 --> 00:10:39.893
It never has to go in an attic.

00:10:39.893 --> 00:10:42.836
If you're doing that, you suck at planning!

00:10:42.836 --> 00:10:48.477
And I promise everybody out there, the 20 square feet 
or so taken up by this stuff in the floor&nbsp;plan

00:10:48.477 --> 00:10:52.733
is absolutely worth being able to get at it without a ladder.

00:10:52.733 --> 00:10:53.892
Priorities, man.

00:10:53.892 --> 00:10:55.107
Get some!

00:10:55.856 --> 00:11:00.941
As I&nbsp;was saying, I go downstairs to the furnace closet, 
turn this down, and then when the cold snap is&nbsp;over,

00:11:00.941 --> 00:11:03.958
I'll wonder why it's not as 
comfortable as I'd like it to be before remembering,

00:11:03.958 --> 00:11:07.793
"Oh right,&nbsp;I turned the humidistat down"
and then I turn it back up.

00:11:07.793 --> 00:11:14.370
Given all that hassle, it sure would&nbsp;be nice if there were humidistats out there that were aware of the outdoor temperature

00:11:14.370 --> 00:11:20.332
and could&nbsp;automatically adjust the indoor 
humidity set point down during those cold snaps.

00:11:20.332 --> 00:11:22.648
Oh, wait.&nbsp;Those exist!

00:11:22.648 --> 00:11:29.453
But, well gosh darn it, they're going to 
need a wire run to an outdoor temperature&nbsp;sensor.

00:11:29.453 --> 00:11:33.772
And this furnace closet is 
pretty much in the dead center of my home.

00:11:33.772 --> 00:11:35.786
So, that's gonna be&nbsp;annoying.

00:11:35.786 --> 00:11:42.310
The easiest thing to do would be to run a wire across the garage and maybe slip it past&nbsp;the garage door seal,

00:11:42.310 --> 00:11:50.863
but I didn't like that idea, and I really didn't like the idea of drilling&nbsp;holes in walls or having random wires going all over the place.

00:11:50.863 --> 00:11:53.367
I've lived in my home for over three&nbsp;years now

00:11:53.367 --> 00:11:59.200
and have been lamenting the difficulty of installing an outdoor temp sensor for a&nbsp;better humidistat the whole time.

00:11:59.200 --> 00:12:05.120
And then about two weeks ago, I finally remembered about that&nbsp;
pipe that brings in outside air for the furnace.

00:12:05.680 --> 00:12:09.485
Yeah, this pipe here, it goes all the way outside.

00:12:09.485 --> 00:12:15.822
The point of this is to allow the furnace to have combustion air without creating negative pressure&nbsp;in the building.

00:12:15.822 --> 00:12:21.717
When this panel is closed up, 
the combustion section of this furnace is effectively&nbsp;outdoors.

00:12:21.717 --> 00:12:27.000
It draws in fresh air through here, which brings in 
enough oxygen to set some methane&nbsp;on fire

00:12:27.000 --> 00:12:31.043
and then pushes the exhaust gases out this other pipe.

00:12:31.043 --> 00:12:36.945
And uh well, I could have just run&nbsp;
the outdoor sensor wire through this pipe the whole time.

00:12:37.980 --> 00:12:40.319
Yeah, better late than never!

00:12:40.319 --> 00:12:46.927
Now,&nbsp;quick note, some of the fancier 
thermostats out there are able to control a humidifier directly.

00:12:46.927 --> 00:12:51.626
I&nbsp;don't have one of those - I just have a basic Nest
which irritates me for several reasons,

00:12:51.626 --> 00:12:55.036
but&nbsp;mostly works and I somewhat begrudgingly put up with.

00:12:55.036 --> 00:13:01.834
Luckily, the people who built my home&nbsp;were kind enough to not cheap out and actually ran seven conductor thermostat wire

00:13:01.834 --> 00:13:04.559
between my&nbsp;furnace and the thermostat.

00:13:04.559 --> 00:13:09.734
And this means I could upgrade 
to a fancier Nest or some other smart&nbsp;thermostat

00:13:09.734 --> 00:13:15.660
which knows the outside temperature
 through the internet and then allowed it to&nbsp;control the humidifier.

00:13:15.660 --> 00:13:20.303
But quite frankly, I am trusting 
internet-based solutions less and less&nbsp;these days.

00:13:20.303 --> 00:13:22.715
So, I decided not to go that route.

00:13:22.715 --> 00:13:26.384
Instead, I searched for a new dedicated&nbsp;humidistat.

00:13:26.384 --> 00:13:31.829
And then I discovered, wow, 
this is a much rarer product than I imagined.

00:13:31.829 --> 00:13:33.879
I mean, in hindsight, I kind of get it.

00:13:33.879 --> 00:13:37.110
When you buy a humidifier, it's going to come with one&nbsp;of these.

00:13:37.110 --> 00:13:42.409
But my humidifier apparently came with 
this dumb one, and I want a smarter one.

00:13:42.409 --> 00:13:49.022
And&nbsp;since apparently nobody but specialty supply houses stocks these things, off to Amazon I&nbsp;went.

00:13:49.022 --> 00:13:52.821
I found this Honeywell model as well as this Aprilaire model

00:13:52.821 --> 00:13:56.346
and this suspicious clone of&nbsp;the Aprilaire model.

00:13:56.346 --> 00:14:02.519
Since I have an Aprilaire 700 series 
and this claims to be compatible with that&nbsp;humidifier,

00:14:02.519 --> 00:14:06.183
I figured I'll just get the Aprilaire 60 humidity control.

00:14:06.183 --> 00:14:07.677
So I did.

00:14:07.677 --> 00:14:15.165
Annoyingly,&nbsp;the product listing gave no information on how long the outdoor air temperature sensor&nbsp;wire was.

00:14:15.165 --> 00:14:22.434
I'd need about 30 feet of wire and I figured it would be reasonable for them to&nbsp;include perhaps 50 feet of wire.

00:14:22.434 --> 00:14:25.595
But nope, it was about 2 feet long.

00:14:25.595 --> 00:14:29.065
No big deal. I have a&nbsp;soldering iron and I know how to use it.

00:14:29.065 --> 00:14:32.508
So, the first step was to run a wire through that pipe.

00:14:32.508 --> 00:14:39.089
I&nbsp;made a stop at everybody's favorite suspiciously cheap tool store and got myself a suspiciously&nbsp;cheap 50-ft fishtape.

00:14:39.089 --> 00:14:42.567
I'm sorry, no, it's a 50 Fish T ape.

00:14:43.459 --> 00:14:47.989
I tried to run the fishtape directly&nbsp;
through where the pipe ends inside the furnace,

00:14:47.989 --> 00:14:53.295
but I wasn't too hopeful that that would work 
as&nbsp;there's a lot of bendy bendy in those pipes.

00:14:53.295 --> 00:14:55.758
And indeed, it didn't work.

00:14:55.758 --> 00:15:00.058
No big deal. I figured&nbsp;I'd just drill a hole in this last 90 here,

00:15:00.058 --> 00:15:05.360
which was probably the start of a straight shot&nbsp;
all the way to where the pipe comes out the wall.

00:15:05.920 --> 00:15:11.958
After double and triple-checking that I was about&nbsp;
to drill through the intake pipe and not the&nbsp;exhaust pipe,

00:15:11.958 --> 00:15:13.247
I made my hole.

00:15:13.247 --> 00:15:19.727
And the fishtape&nbsp;went in nice and smooth 
for a good long while, but then it hit something.

00:15:19.727 --> 00:15:23.866
I tried and tried and&nbsp;wiggled and wiggled, 
but it was just not going to budge.

00:15:23.866 --> 00:15:25.816
That was annoying.

00:15:25.816 --> 00:15:29.179
But then I remembered&nbsp;
a trick I saw on the internet somewhere.

00:15:29.179 --> 00:15:34.835
I took some lightweight twine and tied it to the end of&nbsp;a shopping bag, and then I stuffed it into the pipe.

00:15:34.835 --> 00:15:40.879
Then I went outside with my vacuum cleaner,&nbsp;
which had an attachment that fit nearly perfectly into that pipe

00:15:40.879 --> 00:15:42.916
and gave it a toot.

00:15:42.916 --> 00:15:48.544
I am terribly&nbsp;sorry that I left my mic kit plugged into the camera because there's no sound for this clip, \

00:15:48.544 --> 00:15:51.296
but&nbsp;I'll dub it with what I imagine it sounded like.

00:15:51.296 --> 00:15:53.095
[fwbbslrpptty-yoop]

00:15:54.000 --> 00:15:58.246
I honestly could not believe 
how well&nbsp;that worked, but I was sure glad it did.

00:15:58.246 --> 00:16:00.767
Too bad I already drilled that hole, I&nbsp;guess.

00:16:00.767 --> 00:16:07.860
With the bag and the twine now at the other end of the pipe, I pulled it out&nbsp;and tied a wire to the end of the twine.

00:16:07.860 --> 00:16:14.587
I wasn't planning to use speaker wire for this, but since&nbsp;
this pipe is apparently twistier than I realized,

00:16:14.587 --> 00:16:17.895
I wanted something relatively thick and strong.

00:16:17.895 --> 00:16:21.498
Then I went back inside and started pulling on the twine.

00:16:21.498 --> 00:16:24.375
It was going so well, but then...

00:16:25.374 --> 00:16:26.132
But!

00:16:26.132 --> 00:16:27.648
A Christmas miracle!

00:16:27.648 --> 00:16:32.370
It made it past that hole I drilled, 
and with some picks, I was able to get&nbsp;it out.

00:16:32.370 --> 00:16:34.857
Good thing I already drilled that hole, I guess.

00:16:34.857 --> 00:16:37.933
I pulled out about 10 ft of wire from that&nbsp;hole,

00:16:37.933 --> 00:16:43.926
and then I went outside, cut it to length, 
and soldered the sensor wire to the new end I&nbsp;just made.

00:16:43.926 --> 00:16:51.385
Then I went back inside and pulled the wire back until the sensor was dangling down&nbsp;at the very end of the intake pipe.

00:16:51.385 --> 00:16:53.988
And that's where I decided to leave it.

00:16:53.988 --> 00:17:00.773
Then I taped the wire&nbsp;in place and made a 
big ol' booger of silicone to seal up that hole in the pipe.

00:17:00.773 --> 00:17:03.988
Now, some of you,&nbsp;
including the writers of the instruction manual,

00:17:03.988 --> 00:17:11.966
might be concerned about how close the intake&nbsp;pipe is to the exhaust pipe, but I am confident that this location is fine.

00:17:11.966 --> 00:17:18.480
For one, when the&nbsp;furnace is running, it will be drawing fresh air up and through the tube past the sensor,

00:17:18.480 --> 00:17:20.725
so the heat from the exhaust shouldn't matter.

00:17:21.440 --> 00:17:26.481
My water heater exhaust is also in this area,&nbsp;
which could potentially affect it.

00:17:26.481 --> 00:17:33.780
But unless I'm actually using hot water, the water heater&nbsp;only comes on for about 5 minutes every few hours&nbsp;or so.

00:17:33.780 --> 00:17:36.733
And one day, I want to get a heat pump&nbsp;water heater.

00:17:36.733 --> 00:17:43.437
I could have, of course, actually pulled the wire out of the bottom of that pipe and&nbsp;mounted the sensor somewhere if I were concerned,

00:17:43.437 --> 00:17:45.335
but I wasn't, so I didn't.

00:17:45.335 --> 00:17:50.795
All right, with the&nbsp;outdoor temp sensor in place, 
it was time to install the new humidistat.

00:17:50.795 --> 00:17:56.026
It needs a 3/4 inch&nbsp;hole 
in the return duct to get a measurement of relative humidity.

00:17:56.026 --> 00:18:00.506
And I was hopeful the existing&nbsp;
humidistat would have a similar hole underneath,

00:18:00.506 --> 00:18:08.049
but no, that one needed a big old hole cut in&nbsp;
the sheet metal, which now presented me with a problem.

00:18:08.049 --> 00:18:13.594
I elected to seal that hole with some&nbsp;
duct tape and mount the new humidistat lower down.

00:18:13.594 --> 00:18:20.527
I didn't have a 3/4 inch drill bit, so I simply&nbsp;abused my 1/2 inch drill bit and made this beautiful hole.

00:18:20.527 --> 00:18:26.641
But with it mounted here, it will now be&nbsp;able to know the humidity of the air which is entering my furnace.

00:18:26.641 --> 00:18:30.598
This is something that I&nbsp;don't quite love about this humidistat.

00:18:30.598 --> 00:18:32.907
For my home, it's perfect.

00:18:32.907 --> 00:18:36.669
I don't actually have any&nbsp;return ducting at all.

00:18:36.669 --> 00:18:43.388
The enclosed bedrooms upstairs have vents installed above the doors&nbsp;which pass air into the hallway.

00:18:43.388 --> 00:18:49.251
And the hallway leads to a switchback staircase which goes all&nbsp;the way down to the lower level where the furnace is.

00:18:49.251 --> 00:18:55.923
And since the main level is basically one big&nbsp;
room, the staircase itself is the return air path

00:18:55.923 --> 00:19:01.116
and all the furnace needs is one 
giant intake vent&nbsp;at the bottom of the stairs.

00:19:01.116 --> 00:19:05.661
That's what's on the other side of the duct 
I've just attached the&nbsp;control to.

00:19:05.661 --> 00:19:12.928
My home's setup means that whenever the furnace blower is running, the humidistat is&nbsp;going to get a pretty accurate reading.

00:19:12.928 --> 00:19:19.868
But I can think of plenty of cases where it would be better&nbsp;
for the humidity sensor to be somewhere else.

00:19:19.868 --> 00:19:26.956
In those cases, you might be better off getting a&nbsp;
fancier thermostat, which can control a humidifier remotely.

00:19:26.956 --> 00:19:31.708
But if your home's HVAC system was&nbsp;
designed reasonably well like mine was,

00:19:31.708 --> 00:19:37.232
taking a reading of the air entering 
the furnace or air&nbsp;handler should work fine.

00:19:37.232 --> 00:19:41.029
And with it now mounted, all that was left was the wiring.

00:19:41.029 --> 00:19:44.318
Here, things are&nbsp;drastically different than before.

00:19:44.318 --> 00:19:49.055
This humidistat has the capability 
to force the furnace fan to&nbsp;run.

00:19:49.055 --> 00:19:55.467
If it hasn't gotten a heating call in an hour, it will kick on the blower so it can stir&nbsp;the air up for a while,

00:19:55.467 --> 00:20:02.125
get an accurate humidity reading, and then if it's too low, it will switch&nbsp;the humidifier on and keep the blower running

00:20:02.125 --> 00:20:05.287
regardless of what the thermostat's commanding.

00:20:05.287 --> 00:20:10.891
This is a pretty neat feature, and it means 
I can remove the fan schedule from my thermostat.

00:20:10.891 --> 00:20:15.019
But&nbsp;it also means this now needs a way to control the furnace.

00:20:15.019 --> 00:20:20.179
But in addition to that, it also wants to&nbsp;
know if the thermostat is calling for heat.

00:20:20.179 --> 00:20:23.745
So it needs some pretty significant wiring changes.

00:20:23.745 --> 00:20:30.157
In fact, it wants to be connected to R and C, giving it a 24 volt power source from the furnace,

00:20:30.157 --> 00:20:33.437
W so it can see a heating call in progress,

00:20:33.437 --> 00:20:38.640
and it wants me to disconnect the thermostat wire&nbsp;
from the G terminal on the furnace

00:20:38.640 --> 00:20:42.494
and instead connect it to the G terminal on the humidistat.

00:20:42.494 --> 00:20:50.364
Then I need to run a new G wire called Gf back from the humidistat and land it on the G terminal&nbsp;in the furnace.

00:20:50.364 --> 00:20:54.234
This setup is what allows the humidistat 
to force the furnace blower on,

00:20:54.234 --> 00:20:58.906
but&nbsp;it will still pass a fan call 
from the thermostat through as normal.

00:20:58.906 --> 00:21:05.197
And finally, of course, I need&nbsp;to connect the humidifier's control wires to the two H terminals on the board

00:21:05.197 --> 00:21:07.663
and the outdoor&nbsp;temperature sensor.

00:21:07.663 --> 00:21:12.558
With that done, all that was needed 
was to turn the furnace back on and&nbsp;test it out.

00:21:12.558 --> 00:21:13.855
Hope I didn't blow anything up.

00:21:16.567 --> 00:21:21.445
[blower noise in background]
I think the outdoor temperature is high&nbsp;enough for it to run

00:21:21.445 --> 00:21:24.336
if I turn it to six, but we'll see.

00:21:24.836 --> 00:21:25.896
[click]

00:21:26.860 --> 00:21:30.939
Uhhh, so the board woke up and the&nbsp;relay definitely clicked

00:21:30.939 --> 00:21:35.728
and it's telling me the humidifier is running, 
but the humidifier is not&nbsp;actually running.

00:21:36.656 --> 00:21:38.282
Well...

00:21:38.282 --> 00:21:43.289
All right, with the help of a multimeter and some troubleshooting, I have&nbsp;figured out what's going on here.

00:21:43.289 --> 00:21:45.709
And now I'm mad!

00:21:45.709 --> 00:21:53.567
So, this thing comes with instructions for hooking&nbsp;it up to an Aprilaire 700 series humidifier, which is what I have.

00:21:53.567 --> 00:21:57.936
And it has a footnote about 
if&nbsp;your humidifier was made before 2007

00:21:57.936 --> 00:22:01.830
(apparently they've been making them like these forever) 
there's some difference in the wiring.

00:22:01.830 --> 00:22:05.423
Well, this humidifier is definitely 
newer than that,&nbsp;but it's not working.

00:22:05.423 --> 00:22:10.713
Well, it turns out I don't have a 700. I have a 700M.

00:22:10.713 --> 00:22:13.554
And you would&nbsp;think, right, the M stands for manual -

00:22:13.554 --> 00:22:20.900
the only difference between those models is you get the&nbsp;
manual control, the one that I just replaced, or this digital control.

00:22:20.900 --> 00:22:27.338
But in fact, the 700M&nbsp;
gets its 24volts AC externally from the furnace.

00:22:27.338 --> 00:22:32.403
And the 700 automatic version 
has its own 24 volt&nbsp;transformer inside.

00:22:32.403 --> 00:22:37.682
And all this is doing is bridging 
these two contacts through this&nbsp;relay.

00:22:37.682 --> 00:22:44.535
But the manual humidifier needs to get 24 volts AC, 
which is going to be possible with this -

00:22:44.535 --> 00:22:48.909
I have to do a little bit of sanity checking 
to make sure I wire it correctly.

00:22:48.909 --> 00:22:55.042
But I'm going&nbsp;to have to jump either 
R or C over to one side of this

00:22:55.042 --> 00:23:02.531
and then basically have that relay send&nbsp;
24 volts up to the humidifier like the original control.

00:23:02.531 --> 00:23:08.753
Now, why on earth does Aprilaire 
choose&nbsp;to distinguish them in this way?

00:23:08.753 --> 00:23:10.993
I don't know, but it's really frustrating.

00:23:10.993 --> 00:23:17.605
And they clearly&nbsp;don't want people figuring out how to wire this digital version to the manual one

00:23:17.605 --> 00:23:19.342
because&nbsp;they just don't even tell you it's possible.

00:23:19.342 --> 00:23:21.964
But it's totally possible. This is just a relay.

00:23:21.964 --> 00:23:27.182
One of these relays does the humidifier. 
The other relay forces the furnace fan on.

00:23:27.182 --> 00:23:34.768
But they&nbsp;do not give you a wiring diagram for how to use this with the manual model, even though it's&nbsp;completely possible.

00:23:35.767 --> 00:23:39.975
[sigh]
I've been meaning to make a video on right to repair for a while.

00:23:39.975 --> 00:23:44.660
This isn't&nbsp;quite part of that, but man.

00:23:44.660 --> 00:23:45.810
This is dumb.

00:23:45.810 --> 00:23:48.295
Okay, my modifications are complete.

00:23:48.295 --> 00:23:53.993
Now, this is&nbsp;going to look very confusing because I don't have - almost none of these wire colors are correct.

00:23:53.993 --> 00:23:57.252
I'm&nbsp;actually using garage door opener sensor wire.

00:23:57.252 --> 00:23:59.699
Uh, yeah, but it should work.

00:23:59.699 --> 00:24:06.070
Basically, I now have red and blue 
(this is 24 volts and common)

00:24:06.070 --> 00:24:10.746
taken off of the input and then I have a separate lead&nbsp;for them.

00:24:10.746 --> 00:24:17.122
So now this thing and the humidifier are wired in parallel.

00:24:17.122 --> 00:24:23.505
But the humidifier's&nbsp;return - 
it's landing on one of the H terminals

00:24:23.505 --> 00:24:26.437
and then the other H terminal 
is coming back to&nbsp;this common point.

00:24:26.437 --> 00:24:33.708
So basically the humidifier 
would run all the time if this relay is closed.

00:24:33.708 --> 00:24:37.271
But when the relay is open it shouldn't run.

00:24:38.960 --> 00:24:45.435
Now, there's really nothing left to do except&nbsp;
turn this back on and hope for the best.

00:24:45.435 --> 00:24:51.434
Now, uh I know it's safe to do this because the&nbsp;
worst thing that would happen

00:24:51.434 --> 00:24:55.283
is I will blow the furnace's power supply fuse.

00:24:55.283 --> 00:24:58.987
And uh it's&nbsp;probably an automotive fuse,
I may even have a spare on hand.

00:24:58.987 --> 00:25:02.248
But it will be easy to&nbsp;get a replacement if I need it.

00:25:02.248 --> 00:25:07.328
It's part of how I know it's safe 
for me to be doing this&nbsp;nonsense.

00:25:07.328 --> 00:25:11.804
Here is the moment of truth, part two.

00:25:16.479 --> 00:25:18.743
Okay, it's on.

00:25:18.743 --> 00:25:20.941
We're going blower activation...

00:25:23.725 --> 00:25:26.094
I'm going to turn that to on.

00:25:26.094 --> 00:25:29.197
Crank this up all&nbsp;the way and hopefully the humidifier comes on.

00:25:31.766 --> 00:25:33.149
What is this test?

00:25:33.149 --> 00:25:37.042
[clack, hissing, whirring] 
Oh, well, that works.

00:25:37.042 --> 00:25:39.815
And look&nbsp;at that! The humidifier is running!

00:25:39.815 --> 00:25:41.453
Now, is the blower actually running?

00:25:41.453 --> 00:25:44.034
It's hard to tell when&nbsp;the humidifier is on as well.

00:25:44.034 --> 00:25:47.372
Oh, for sure it is. So, that worked correctly.

00:25:48.407 --> 00:25:50.760
Want to make sure this&nbsp;actually shuts off now.

00:25:50.938 --> 00:25:52.464
[clunk]

00:25:52.786 --> 00:25:53.653
Awesome.

00:25:53.653 --> 00:26:01.165
With that rather ugly but functional wiring modification, 
this is&nbsp;now working as I expected it to the whole time.

00:26:01.165 --> 00:26:05.588
The humidistat can now energize this relay, 
which&nbsp;forces the furnace fan to run.

00:26:05.588 --> 00:26:10.966
And that allows it to perform its own check 
of the ambient humidity&nbsp;level on an hourly basis.

00:26:10.966 --> 00:26:16.789
If during that check it finds that it's lower than the set point, it will&nbsp;then energize this relay which,

00:26:16.789 --> 00:26:23.986
thanks to those horrible jumpers and wire nuts will now send power&nbsp;up to the humidifier's water valve, which will switch it on.

00:26:23.986 --> 00:26:27.148
And of course, that will increase&nbsp;the humidity in my home.

00:26:27.148 --> 00:26:33.791
But once it reaches the set point, the humidity sensor will detect that,&nbsp;at which point it will turn the humidifier off.

00:26:33.791 --> 00:26:37.436
That will all happen regardless of what my&nbsp;thermostat's doing.

00:26:37.436 --> 00:26:40.880
If though my thermostat is commanding the heat to run,

00:26:40.880 --> 00:26:47.372
the humidistat is now&nbsp;aware of that thanks to the fact that it's hooked up to the W terminal on the furnace board.

00:26:47.372 --> 00:26:54.342
So, as&nbsp;before, if the humidity is below the set point, it will close the relay and send power to the&nbsp;humidifier.

00:26:54.342 --> 00:26:58.516
And once it's satisfied, it shuts the humidifier off.

00:26:58.516 --> 00:27:01.549
Now, none of this is really&nbsp;new.

00:27:01.549 --> 00:27:05.132
My old setup with the humidifier connected to the fan terminal 

00:27:05.132 --> 00:27:11.536
and with my thermostat&nbsp;forcing the fan to run for 15 minutes every hour accomplished the same thing.

00:27:11.536 --> 00:27:17.906
See, I also went into&nbsp;my thermostat's programming to make it command the fan during a heating call.

00:27:17.906 --> 00:27:25.280
Something that's&nbsp;not necessary for my heating system to work, but which allowed the humidifier to run during a heating call, too.

00:27:25.280 --> 00:27:32.026
So, when it comes to the basic functionality 
of the humidifier, I haven't really&nbsp;changed anything.

00:27:32.026 --> 00:27:38.639
But now that this control knows what the outdoor air temperature is, I no longer&nbsp;have to think about that.

00:27:38.639 --> 00:27:45.258
It will automatically reduce the humidity set point as the ambient&nbsp;temperature outside falls.

00:27:45.258 --> 00:27:51.637
This chart here explains how the humidifier will adjust the set&nbsp;
point based on the outdoor temperature reading.

00:27:51.637 --> 00:28:00.613
The recommended setting, five, will allow the&nbsp;humidity to get as high as 45%, but will start lowering it when the outdoor temp is 30° F,

00:28:00.613 --> 00:28:03.468
which&nbsp;is just a hair below freezing.

00:28:03.468 --> 00:28:10.476
I know that my home can handle 45% 
at that temperature just fine so I decided to set it to six.

00:28:10.476 --> 00:28:14.651
And actually, this is my biggest disappointment with this thing.

00:28:14.651 --> 00:28:24.472
I would&nbsp;like setting six to shoot for 50% humidity when it's above freezing outside, but the highest this&nbsp;will ever go is 45%.

00:28:24.472 --> 00:28:27.887
That's not a big difference, but I can notice it.

00:28:27.887 --> 00:28:35.188
Still, I will happily&nbsp;sacrifice that for the peace of mind that this will automatically reduce its output in those cold&nbsp;snaps.

00:28:35.188 --> 00:28:40.598
I haven't had this installed for very long, 
but my thermostat, which has a hygrometer in&nbsp;there,

00:28:40.598 --> 00:28:44.114
is telling me the indoor humidity is hovering around 45%.

00:28:44.114 --> 00:28:47.875
So, it's doing its job&nbsp;and seems to be accurate.

00:28:47.875 --> 00:28:51.824
Or I guess at least my thermostat agrees with it.

00:28:51.824 --> 00:28:53.960
The other thing I&nbsp;don't like about this?

00:28:53.960 --> 00:28:58.117
It won't tell me what it thinks the outdoor temperature is.

00:28:58.117 --> 00:29:05.528
It should throw&nbsp;an error code if the sensor goes bad, 
but what if the sensor is simply drifting over time?

00:29:05.528 --> 00:29:11.511
I'm not&nbsp;going to know that unless the drift is 
bad enough to cause it to over- or under-humidify.

00:29:11.511 --> 00:29:15.487
Since I've&nbsp;installed this, 
the outdoor temperature hasn't fallen much below freezing.

00:29:15.487 --> 00:29:19.745
So, I'm not even&nbsp;sure yet that it's working as intended.

00:29:19.745 --> 00:29:23.594
That's cool since, you know, 
that's the whole reason I&nbsp;did this.

00:29:23.594 --> 00:29:26.542
But, we're supposed to get a cold snap shortly after Christmas,

00:29:26.542 --> 00:29:32.034
and I'll do one of those&nbsp;community posts once we've gone through that. And I'll pin a comment here, too.

00:29:32.034 --> 00:29:35.149
Aside from the&nbsp;absolute ridiculousness that was

00:29:35.149 --> 00:29:42.014
having to figure out my own way to get this Aprilaire humidity&nbsp;controller to work with my Aprilaire humidifier,

00:29:42.014 --> 00:29:44.719
I am very happy to have made this upgrade.

00:29:44.719 --> 00:29:47.085
But&nbsp;to circle back to the beginning of this video,

00:29:47.085 --> 00:29:53.219
while the main point of doing this is to make my&nbsp;humidifier something closer to set-and-forget,

00:29:53.219 --> 00:29:56.940
it's still absolutely not set-and-forget.

00:29:56.940 --> 00:29:59.819
The potential for leaks is still there.

00:29:59.819 --> 00:30:03.877
The potential for a deteriorating water pad is still&nbsp;there.

00:30:03.877 --> 00:30:09.215
And while I hope its outdoor temperature sensor 
will work reliably for years to come,

00:30:09.215 --> 00:30:15.942
the&nbsp;potential for too much humidification 
if it starts drifting in the wrong direction is still there.

00:30:15.942 --> 00:30:21.821
I will absolutely still be monitoring 
my home's humidity level and the function of the humidifier.

00:30:21.821 --> 00:30:28.100
And I suggest that anybody out there with one of these things check on it at least monthly and&nbsp;preferably weekly.

00:30:28.100 --> 00:30:35.199
That I think is the biggest argument for choosing a large freestanding&nbsp;humidifier over one of these things.

00:30:35.199 --> 00:30:38.143
Sure, it's annoying to fill those up with water every&nbsp;day or two,

00:30:38.143 --> 00:30:44.997
especially considering that you'll need to use a water treatment product with those&nbsp;fill-ups to prevent odors and mold growth.

00:30:44.997 --> 00:30:48.068
And of course, they take up space.

00:30:48.068 --> 00:30:55.267
But when you have to&nbsp;keep interacting with it in order for it to keep working, you'll be more likely to notice problems.

00:30:55.267 --> 00:31:00.890
Plus, if its tank were to start leaking, at most you'll have a few gallons of water on the floor.

00:31:00.890 --> 00:31:07.175
This thing's plumbed to full water pressure, 
which means leaks could be much more catastrophic.

00:31:07.175 --> 00:31:11.871
I have a floor drain in this furnace closet, 
so I'm not too too worried about that.

00:31:11.871 --> 00:31:17.462
But still, it&nbsp;could cause 
major damage to my furnace, and that's not good.

00:31:17.462 --> 00:31:23.227
But I must admit, it has been very nice&nbsp;
to have this machine keeping the air comfortable

00:31:23.227 --> 00:31:27.220
without having to fill up a weird 
2 gallon bottle&nbsp;every couple of days.

00:31:27.220 --> 00:31:31.063
And now that the humidistat knows the outdoor air temperature,

00:31:31.063 --> 00:31:35.974
I'll be&nbsp;slightly more at peace 
knowing that I can't forget to turn it down.

00:31:35.974 --> 00:31:40.423
I'm still going to be checking&nbsp;on the humidifier 
every week or so to make sure the fan is spinning

00:31:40.423 --> 00:31:42.718
and that there isn't water&nbsp;where there shouldn't be.

00:31:42.718 --> 00:31:48.061
Plus, of course, I'll be checking that 
the controller I installed actually&nbsp;does its job.

00:31:48.061 --> 00:31:53.878
Assuming it does, though, this is as close to set-and-forget as you can reasonably&nbsp;make one of these,

00:31:53.878 --> 00:31:56.245
and that makes me happy.

00:31:57.067 --> 00:31:59.822
♫ moistenedly smooth jazz ♫

00:32:00.595 --> 00:32:03.624
A few things I didn't mention in the main&nbsp;body of the video:

00:32:03.624 --> 00:32:09.561
First, like my old setup, I'll have to remember to turn this off when the&nbsp;weather gets warm.

00:32:09.561 --> 00:32:14.611
If I don't, it may try to add humidity when that's the last thing I want.

00:32:14.611 --> 00:32:16.309
Yay,&nbsp;Midwest.

00:32:16.309 --> 00:32:23.833
Second, at time of filming, I haven't yet verified whether or not it knows the thermostat&nbsp;is commanding the fan.

00:32:23.833 --> 00:32:28.269
It should, but I didn't think to actually test that before I got here and&nbsp;shot the talking head.

00:32:28.269 --> 00:32:29.579
Here's the answer:

00:32:29.579 --> 00:32:35.110
I just confirmed that yes, it does turn on the 
humidifier&nbsp;when the thermostat gives it a fan call.

00:32:35.110 --> 00:32:37.455
So, that is working as I expected.

00:32:37.455 --> 00:32:41.538
And third, this thing's&nbsp;humidity sensor does a reasonable job,

00:32:41.538 --> 00:32:48.454
but I have noticed that the displayed humidity falls quite&nbsp;
dramatically as soon as I open the door to the furnace closet.

00:32:48.454 --> 00:32:52.716
It drops by about 5% even when the&nbsp;blower is running.

00:32:52.716 --> 00:32:58.285
This is a bit puzzling to me as it's in the same room 
that the furnace is pulling&nbsp;air from.

00:32:58.285 --> 00:33:02.663
And based on what my 
thermostat is telling me, it doesn't seem to matter.

00:33:02.663 --> 00:33:09.135
But clearly&nbsp;the sensor is being affected 
by the air around it and not just inside the duct.

00:33:09.135 --> 00:33:12.231
That makes complete&nbsp;sense based on this thing's design.

00:33:12.231 --> 00:33:18.320
And it would really be improved if it had some sort of remote&nbsp;sensor you could shove deep into the duct.

00:33:18.320 --> 00:33:24.109
Plus, that would mean you could mount this control&nbsp;
somewhere it's more visible if you wanted.

00:33:24.109 --> 00:33:29.911
I know there are plenty of climates out there&nbsp;where the idea of wanting to add moisture to the air is abhorrent,

00:33:29.911 --> 00:33:37.198
but I'm surprised how&nbsp;terrible the options seem to be 
for central ducted humidifier controls.

00:33:37.198 --> 00:33:40.674
They are simple&nbsp;things, yes, 
but we could be doing so much better.

00:33:43.422 --> 00:33:47.256
...humidistat the whole time and then about 2 weeks later -

00:33:47.256 --> 00:33:48.745
oh shoot.

00:33:48.745 --> 00:33:53.532
Yeah, it used to be white and now it's pink and chunky fer-

00:33:53.532 --> 00:33:55.884
ah, it's crunchy!

00:33:55.884 --> 00:33:57.469
Crunchy,&nbsp;not chunky.

00:33:57.469 --> 00:33:58.655
Eurgh.

00:33:58.655 --> 00:34:04.926
This thing is basically a swamp cooler and will drop the temperature of the air&nbsp;leaving the vents if it's running.

00:34:04.926 --> 00:34:07.140
But the pad...

00:34:09.520 --> 00:34:11.318
I missed the word if.

00:34:12.174 --> 00:34:15.199
Then I&nbsp;taped the wire in place and made a...

00:34:15.199 --> 00:34:16.687
ah, farts.

00:34:16.687 --> 00:34:19.646
That's what's on&nbsp;the other side of the duct of...

00:34:19.646 --> 00:34:20.477
Farts.

00:34:20.477 --> 00:34:21.615
Farts!!

00:34:23.578 --> 00:34:30.195
So those of you who were looking at that wiring diagram closely might have noticed that it was showing the transformer in the automatic version and how the relay breaks that circuit.

00:34:30.195 --> 00:34:35.117
I was so confused by the idea of the transformer not being in the furnace that it didn't even register what the diagram explained.

00:34:35.117 --> 00:34:38.242
Sometimes a multimeter brings a faster answer!